Press
Menu
Press Digit Select
Key
Press Value Select
Key
__0000
Display mode
0 Normal, overload to exponential format
1 Normal, overload to 999999
2 1 right-hand dummy zero
3 2 right-hand dummy zeros
4 Time display in seconds
5 Time display in HH.MM.SS format
6 Remote display (H, K, L commands)
7 Single-value remote display
8 Show 1
st
string value, slaved to another meter
9 Show 2
nd
string value, slaved to another meter
A Show 3
rd
string value, slaved to another meter
B Show 4
th
string value, slaved to another meter
C Custom Start, Stop, Skip, Show
__0000 Counter mode 0 Basic counter 1 Extended counter
2 Extended counter, custom curve linearization
__0000 Square root 0 Linear rate input. 1 Square root rate input.
ConFiG
Configu-
ration
__0000 Not applicable 0 Set to 0.
dSPyno
Display #
____01
PEAK key action
0 Display Peak 1 Display Valley
2 Peak (1
st
push), Valley (2
nd
push)
____01 Item to display
after Meter Reset*
1 Item #1* 2 Item #2* 3 Item #3*
GAtE_t
Gate time*
_000.00 _000.00 _000.00
_000.00 _000.00
Select digit to flash.
Select 0 thru 9 for flashing digit to set gate time* in
seconds. Decimal point location is fixed for 10 ms
resolution.
.ti_Out.
Time-out*
_000.00 _000.00 _000.00
_000.00 _000.00
Select digit to flash.
Select 0 thru 9 for flashing digit to set time-out* in
seconds. Decimal point location is fixed for 10 ms
resolution.
_00000
Handling of overshoot
count at end of batch.
0 Do not count extra pulses after Preset. Add
Preset values to Grand Total.
1 Count all pulses. Add Preset values to Grand
Total.
2 Do not count extra pulses after Preset. Add
Preset values to Grand Total.
3 Count extra pulses after Preset. Add actual
Batch Totals to Grand Total.
_00000
Count direction
0 Reset batch to 0 and count up to Setpoint 1.
1 Reset batch to Setpoint 1 and count down.
bAtCH
Batch setup
_00000
Batch triggering
0 Use internal gate time as delay between batches
1 Use External Input B to trigger each new batch.