Laurel-electronics LAUREATE SERIES Serial Comunications Uživatelský manuál Strana 8

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 40
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 7
DIGIT SELECT KEY VALUE SELECT KEY
MENU KEY
00000
RS485 full or half duplex
00000
Meter recognition character
and start & stop character
00000
RS232 RTS type
00000
Carriage return (and LF)
00000
Data sent via communications
(if BCD, only 1 item allowed)
Ser 3
Serial interface setup
(only enabled if communica-
tions board installed)
0 Full duplex
1 Half duplex
0 " * " , none, CR
1 Spl, none, CR
2 " * " , Spl, Spl
3 Spl , Spl, Spl
0 Nonlatching RTS
1 Latching RTS
0 Only at end of all items
1 At end of each item
0 All active items sent
1 Item #1 only
2 Item #2 only (if active)
3 Item #3 only (if active)
4 Peak value
5 All active items + peak
1.5 SERIAL INTERFACE SETUP - COUNTER ONLY
00000
RS485 full or half duplex
00000
Special start &stop character
00000
RS232 RTS type
00000
Carriage return (and LF, if
selected)
00000
Data sent via communications
(if BCD, only 1 item allowed)
Ser 3
Serial interface setup
(only enabled if communica-
tions board installed)
0 Full duplex
1 Half duplex
0 Normal format, continuous
1 Special start and stop
0 Nonlatching RTS
1 Latching RTS
0 Only at end of all items
1 At end of each item
(If alarm, only at end)
0 Net and Gross
1 Net only
2 Gross only
3 Peak only (net or gross)
4 Net & gross & peak
1.6 SERIAL INTERFACE SETUP - SCALE METER ONLY