SERIAL INPUT METER
& REMOTE DISPLAY
LAUREATE SERIES 2
OWNERS MANUAL
Now with Ethernet
LAUREL Electronics Inc.
3183-G Airway Ave, Costa Mesa, CA, 92626, USA
Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 -

1 SERIAL INPUT METER & REMOTE DISPLAY LAUREATE SERIES 2 OWNERS MANUAL Now with Ethernet L

Strany 2 - 2. TABLE OF CONTENTS

10 ALARMS Key. Pressing ALARMS once displays the setpoint for Alarm 1. Pressing it again displays the setpoint for Alarm 2. Pressing it again retur

Strany 3 - 3. PRODUCT INTRODUCTION

11 9. ENABLING & LOCKING OUT MENU ITEMS For security reasons and ease of operation, any and all menu items may be disabled or "locked out

Strany 4 - 5. SAFETY CONSIDERATIONS

12 10. SERIAL INPUT METER / REMOTE DISPLAY CONFIGURATION Serial input meter / remote display operation of a counter utilizes a Basic counter main

Strany 5

13 SELECTED FRONT PANEL SETUP ITEMS FOR SERIAL INPUT METER (not consecutive) If the MENU key does not work, see Section 9 “Enabling & Locking

Strany 6

14 11. SERIAL COMMUNICATIONS OPTIONS A serial communications board is required for serial input meter / remote display operation. The communication

Strany 7 - 7. MECHANICAL ASSEMBLY

15 USB Board No jumpers required. Basic Ethernet Board No jumpers needed. RS232 Board e - Normal operation. f - Slave display to RS232 from

Strany 8

16 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Key Press Digit Se

Strany 9 - 8. FRONT PANEL SETUP KEYS

17 12. DUAL & QUAD RELAY OUTPUT OPTIONS An optional relay board may be installed in the meter main board at plug position P2, ad

Strany 10

18 KEYSTROKES FOR SETUP If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press Menu Press Digit Sele

Strany 11 - Enabled / Disabled Menu Items

19 Press Menu Press Digit Select Key Press Value Select Key 00000 Relay state when alarm is active. 0 Relay 3 on Relay 4 on 1 Relay

Strany 12

2 1. ORDERING GUIDE Configure a model number in this format: L5002, CBL01 L... ... Serial input meter Includes screw terminal

Strany 13

20 13. SINGLE & DUAL ANALOG OUTPUT OPTIONS Two versions of an analog board may be installed in the meter at rear panel jack position J4, adjace

Strany 14

21 KEYSTROKES FOR SETUP OF DUAL ANALOG OUTPUT BOARD If the MENU key does not work, see Section 9 “Enabling & Locking Out Menu Items.” Press

Strany 15

22 14. INSTRUMENT SETUP VIA PC OVERVIEW Our serial input meters are easily programmed using a PC with an RS232 port and Instru-ment Setup (IS) Soft

Strany 16

23 In the Establish Communications screen, select your Com Port and 9600 as the Baud Rate. You will be able to change your proto

Strany 17

24 Click on Counter => Get Setup to retrieve the current setup information from your counter, then on View => Setup, which will take you to th

Strany 18

25 Input+Scaling tab. Works only with the Custom ASCII protocol, not the Modbus protocol, since a meter cannot listen to commands while i

Strany 19

26 Click on the Relay Alarms tab to set up your meter’s two or four optional relays. The same digital source is used for all relays and must

Strany 20

27 Click on the Communication tab to view the communication parameters that you used to establish default communications with your transmitter. You

Strany 21

28 Click on the Analog Out tab to scale your meter’s optional single or dual analog outputs. Item 3 must be selected as the Analog Output Source. Wi

Strany 22 - 14. INSTRUMENT SETUP VIA PC

29 15. SPECIFICATIONS DISPLAY Type ...6 LED digits, 7-segment, 14.2mm, plus 4 LED indicators Digit

Strany 23

3 3. PRODUCT INTRODUCTION Our Serial Input Meter (or remote display) accepts serial data from computers, program-mable controllers,

Strany 24

- 30 - Scaling of Reading for Full Scale Output... -999,999 to +999,999 Isolation rating between signal co

Strany 25

- 31 - 16. GLOSSARY OF TERMS Alarm, latched: An alarm which stays actuated until reset. Latched alarms can shut down machinery or a

Strany 26

- 32 - 17. WARRANTY Laurel Electronics Inc. warrants its products against defects in materials or workmanship for a period of one year from the dat

Strany 27

4 4. RECEIVING & UPACKING Your serial input meter was carefully tested and inspected prior to shipment. Should the meter be damaged in shipm

Strany 28

5 6. CONNECTOR WIRING INFORMATION CONNECTORS Connectors for signal and power are U/L rated screw-clamp terminal blocks that plug into

Strany 29 - 15. SPECIFICATIONS

6 P3 - SERIAL COMMUNICATIONS P4 - ANALOG OUTPUT 654321ISO GNDISO GNDRXTXRTSISO GNDISO GNDISO GNDRXTXRTSISO GNDGNDTXRXRTSRS232 INTERFACE

Strany 30

7 7. MECHANICAL ASSEMBLY REMOVING THE REAR PANEL First remove any connectors. Use one hand to press in the two sides of the rear of

Strany 31 - 16. GLOSSARY OF TERMS

8 Note: Corresponding main board and option board connectors have the same number of electrical lines. When an option board is correctly

Strany 32 - 17. WARRANTY

9 8. FRONT PANEL SETUP KEYS Counter Front Panel There are four front panel keys, which change function for the Run Mode and Menu Mode, effective