- 29 -
7 = Remote Display, Value
8 = 1st Value in String
9 = 2nd Value in String
A = 3rd Value in String
B = 4
th
Value in String
C = Remote Display using Start, Stop, Skip,
Show Characters
78 004E Lockout 1 0 = Enabled, 1 = Locked out
Bit 0 Filter
Bit 1 Gate Time, Timeout, Batch, Preset, Pulses, Cutoff
Bit 2 Setup, Config, Display Number
Bit 3 Input Type
Bit 4 Setpoint Programming
Bit 5 Alarm Config, Deviation / Hysteresis
Bit 6 Scale, Offset, Resolution, 2 Coordinates
Bit 7 Slope, Decimal Points
79 004F Lockout 2 0 = Enabled, 1 = Locked out
Bit 0 Change Item# displayed
Bit 1 Calibration
Bit 2 Serial Comm Config
Bit 3 Analog Out Scaling & Setup
Bit 4 Front Panel Meter Reset
Bit 5 Front Panel Function Reset
Bit 6 View Setpoints
Bit 7 View Peak
80 50 Batch
Operation
Bit 0 0 = Display “rEADy” after Reset
1 = Start
Bit 1 0 = Item2 is Grand Total
1 = Item2 is Total Number of Batches
Bit 2 0 = Gate Time resets
1 = Control Input 2 resets
Bit 3 0 = Reset to Zero, Count Up
1 = Reset to SETPT1, Count Down
Bits 5:4 Residual Input
0,2 = Input Discard, Grand Total Discard
1 = Input Accept, Grand Total Discard
3 = Input Accept, Grand Total Accept