used here, remove jumper c of E10 that was placed for the test in A. above.
C. From the manufacture's specifications for the encoder, determine the number of cycles
per revolution. Multiply this by 1, 2, or 4 depending on the selection of X1, X2 or X4
counting and multiply that result by the counter scale factor. Put the final result in the
counter Menu item, PULSES.
5. Finally, follow the procedure outlined above under the heading titled, MECHANICAL
ZERO.
13.6 MANUFACTURER'S OF OPTICAL ENCODERS
ALLEN BRADLEY
Current Sink, Open Collector and Line Driver CCW rotation
A Channel
B Channel
Zero Index
Current Source CCW rotation
A Channel
B Channel
Zero Index
BEI
Models H25, L25, E25, MOD5500, MOD5600 CCW rotation viewing shaft end
A Channel
B Channel
Zero Index
Zero Index (gated)
-37-